Beitrag zur Vorbemessung der Biegeverstärkung von Stahlbetonbauteilen mit Rechteckquerschnitt mittels aufgeklebten CFK-Lamellen / / Cevin Stiehl.

"Since 2012, the subsequent reinforcement of reinforced concrete components with bonded reinforcement has been regulated in a separate guideline. This includes the dimensioning of the adhesively bonded strips made of carbon fiber reinforced plastic (CFRP), which, in addition to the complex iter...

Full description

Saved in:
Bibliographic Details
VerfasserIn:
Place / Publishing House:[Place of publication not identified] : : HTWK Leipzig - OA-Hochschulverlag,, 2020.
Year of Publication:2020
Language:German
Physical Description:1 online resource (252 pages) :; illustrations
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02788nam a2200313 i 4500
001 993603012204498
005 20230515190138.0
006 m o d
007 cr |||||||||||
008 230515s2020 xx a o 000 0 ger d
024 7 |a 10.33968/9783966270021-00  |2 doi 
035 |a (CKB)5470000000566828 
035 |a (NjHacI)995470000000566828 
035 |a (EXLCZ)995470000000566828 
040 |a NjHacI  |b eng  |e rda  |c NjHacl 
050 4 |a S495  |b .S754 2020 
082 0 4 |a 630  |2 23 
100 1 |a Stiehl, Cevin,  |e author. 
245 1 0 |a Beitrag zur Vorbemessung der Biegeverstärkung von Stahlbetonbauteilen mit Rechteckquerschnitt mittels aufgeklebten CFK-Lamellen /  |c Cevin Stiehl. 
264 1 |a [Place of publication not identified] :  |b HTWK Leipzig - OA-Hochschulverlag,  |c 2020. 
300 |a 1 online resource (252 pages) :  |b illustrations 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
588 |a Description based on publisher supplied metadata and other sources. 
520 |a "Since 2012, the subsequent reinforcement of reinforced concrete components with bonded reinforcement has been regulated in a separate guideline. This includes the dimensioning of the adhesively bonded strips made of carbon fiber reinforced plastic (CFRP), which, in addition to the complex iterative bending design, have a very complex bonding behavior. For this purpose, the German Committee for Structural Concrete developed a model for the verification based on experimental evaluations, in which the occurring tensile forces are partly transferred into the component via intermediate elements (partial distances between flexural cracks). Simultaneously, simplified but more inaccurate verification formats were made available to reduce the complexity of the verification. For an early assessment of the use of bonded CFRP strips, different tools have been developed in this paper for reinforced concrete components with a rectangular cross-section depending on the different verification formats. For this purpose, the design parameters were considered separately for pure bending strength and bonding behavior. For a simple calculation, tables for the design with dimensionless coefficients were obtained by analogy with the reinforced concrete construction, with which the required cross-section area for the CFRP strips can be determined by means of a limited stretching from the simplified verification of the flexural load bearing capacity. For a more economical solution, the more precise verification of the force transmission on the intermediate elements was configured in an Excel workbook, because this results in an extraordinary iterative calculation effort.". 
546 |a German. 
650 0 |a Electronics engineers. 
650 0 |a Agriculture. 
776 |z 3-96627-001-3 
906 |a BOOK 
ADM |b 2023-06-09 07:03:57 Europe/Vienna  |f System  |c marc21  |a 2021-06-12 22:12:12 Europe/Vienna  |g false 
AVE |i DOAB Directory of Open Access Books  |P DOAB Directory of Open Access Books  |x https://eu02.alma.exlibrisgroup.com/view/uresolver/43ACC_OEAW/openurl?u.ignore_date_coverage=true&portfolio_pid=5337781120004498&Force_direct=true  |Z 5337781120004498  |b Available  |8 5337781120004498