Modelling the human cardiac fluid mechanics. 2nd ed

In the second edition of the article a virtual heart modelsimulating the flow in the active left human ventricle andatrium is presented. Because in vivo myocardium data is notavailable, the movement of the active ventricle and its atriumis given by three-dimensional, time-dependent invivo image data...

Full description

Saved in:
Bibliographic Details
:
Year of Publication:2006
Language:English
Physical Description:1 electronic resource (39 p. p.)
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02326nam-a2200325z--4500
001 993559178304498
005 20231214133143.0
006 m o d
007 cr|mn|---annan
008 202102s2006 xx |||||o ||| 0|eng d
035 |a (CKB)4920000000101769 
035 |a (oapen)https://directory.doabooks.org/handle/20.500.12854/53748 
035 |a (EXLCZ)994920000000101769 
041 0 |a eng 
100 1 |a Oertel, HerbertSpiegel, KathrinDonisi, Sven  |4 auth 
245 1 0 |a Modelling the human cardiac fluid mechanics. 2nd ed 
260 |b KIT Scientific Publishing  |c 2006 
300 |a 1 electronic resource (39 p. p.) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
520 |a In the second edition of the article a virtual heart modelsimulating the flow in the active left human ventricle andatrium is presented. Because in vivo myocardium data is notavailable, the movement of the active ventricle and its atriumis given by three-dimensional, time-dependent invivo image dataof a nuclear spin MRI tomograph. The passive part of the virtualheart model consists of a model aorta and of two-dimensionallymodelled heart valves. As the flow is actively driven by theventricle and atrium, a coupling off low and structure isnecessary to take into account the deviation of the aorta andthe closing and opening of the heart valves. This coupling isreplaced by the movement given by MRI tomograph and ultrasonicDoppler echocardiography, since we focus on the flow simulationin the left pumping ventricle. The flow simulation is performedby a validated commercial software package that uses the finitevolume method. The flow resistance of the circulation throughthe body is taken into account with a simplified circulationmodel. The article shows how the virtual heart model can be usedto predict flow losses and flow structures due to pathologicalventricle contraction defects. It provides as an example theflow simulation of an unhealthy human ventricle with ananeurysm. The flow structure and flow losses are consideredbefore and after surgery. 
546 |a English 
653 |a Herzmuskel 
653 |a NMR-Tomographie 
653 |a Herzkrankheit 
653 |a Numerische Strömungssimulation 
653 |a Herz 
653 |a in vivo 
776 |z 3-86644-087-1 
906 |a BOOK 
ADM |b 2023-12-15 05:44:28 Europe/Vienna  |f system  |c marc21  |a 2019-11-10 04:18:40 Europe/Vienna  |g false 
AVE |i DOAB Directory of Open Access Books  |P DOAB Directory of Open Access Books  |x https://eu02.alma.exlibrisgroup.com/view/uresolver/43ACC_OEAW/openurl?u.ignore_date_coverage=true&portfolio_pid=5338238120004498&Force_direct=true  |Z 5338238120004498  |b Available  |8 5338238120004498