Data-driven Methods for Fault Localization in Process Technology

Control systems at production plants consist of a large number of process variables. When detecting abnormal behavior, these variables generate an alarm. Due to the interconnection of the plant's devices the fault can lead to an alarm flood. This again hides the original location of the causing...

Full description

Saved in:
Bibliographic Details
Superior document:Karlsruher Schriften zur Anthropomatik / Lehrstuhl für Interaktive Echtzeitsysteme, Karlsruher Institut für Technologie ; Fraunhofer-Inst. für Optronik, Systemtechnik und Bildauswertung IOSB Karlsruhe
:
Year of Publication:2013
Language:English
Series:Karlsruher Schriften zur Anthropomatik / Lehrstuhl für Interaktive Echtzeitsysteme, Karlsruher Institut für Technologie ; Fraunhofer-Inst. für Optronik, Systemtechnik und Bildauswertung IOSB Karlsruhe
Physical Description:1 electronic resource (XVIII, 194 p. p.)
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 01698nam-a2200337z--4500
001 993545437704498
005 20231214132819.0
006 m o d
007 cr|mn|---annan
008 202102s2013 xx |||||o ||| 0|eng d
020 |a 1000036427 
035 |a (CKB)4920000000101914 
035 |a (oapen)https://directory.doabooks.org/handle/20.500.12854/44557 
035 |a (EXLCZ)994920000000101914 
041 0 |a eng 
100 1 |a Kühnert, Christian  |4 auth 
245 1 0 |a Data-driven Methods for Fault Localization in Process Technology 
260 |b KIT Scientific Publishing  |c 2013 
300 |a 1 electronic resource (XVIII, 194 p. p.) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a Karlsruher Schriften zur Anthropomatik / Lehrstuhl für Interaktive Echtzeitsysteme, Karlsruher Institut für Technologie ; Fraunhofer-Inst. für Optronik, Systemtechnik und Bildauswertung IOSB Karlsruhe 
520 |a Control systems at production plants consist of a large number of process variables. When detecting abnormal behavior, these variables generate an alarm. Due to the interconnection of the plant's devices the fault can lead to an alarm flood. This again hides the original location of the causing device. In this work several data-driven approaches for root cause localization are proposed, compared and combined. All methods analyze disturbed process data for backtracking the propagation path. 
546 |a English 
653 |a Time series 
653 |a Signal processing 
653 |a Data Mining 
653 |a System identification 
653 |a Causality 
776 |z 3-7315-0098-1 
906 |a BOOK 
ADM |b 2023-12-15 05:31:42 Europe/Vienna  |f system  |c marc21  |a 2019-11-10 04:18:40 Europe/Vienna  |g false 
AVE |i DOAB Directory of Open Access Books  |P DOAB Directory of Open Access Books  |x https://eu02.alma.exlibrisgroup.com/view/uresolver/43ACC_OEAW/openurl?u.ignore_date_coverage=true&portfolio_pid=5337963890004498&Force_direct=true  |Z 5337963890004498  |b Available  |8 5337963890004498