Analysis of Atrial Electrograms
This work provides methods to measure and analyze features of atrial electrograms - especially complex fractionated atrial electrograms (CFAEs) - mathematically. Automated classification of CFAEs into clinical meaningful classes is applied and the newly gained electrogram information is visualized o...
Saved in:
Superior document: | Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering |
---|---|
: | |
Year of Publication: | 2012 |
Language: | English |
Series: | Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering
|
Physical Description: | 1 electronic resource (VI, 214 p. p.) |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
993545325704498 |
---|---|
ctrlnum |
(CKB)4920000000101599 (oapen)https://directory.doabooks.org/handle/20.500.12854/40818 (EXLCZ)994920000000101599 |
collection |
bib_alma |
record_format |
marc |
spelling |
Schilling, Christopher auth Analysis of Atrial Electrograms KIT Scientific Publishing 2012 1 electronic resource (VI, 214 p. p.) text txt rdacontent computer c rdamedia online resource cr rdacarrier Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering Open access Unrestricted online access star This work provides methods to measure and analyze features of atrial electrograms - especially complex fractionated atrial electrograms (CFAEs) - mathematically. Automated classification of CFAEs into clinical meaningful classes is applied and the newly gained electrogram information is visualized on patient specific 3D models of the atria. Clinical applications of the presented methods showed that quantitative measures of CFAEs reveal beneficial information about the underlying arrhythmia. English Classification Catheter Ablation Complex Fractionated Atrial Electrograms Atrial Fibrillation Signal Processing 3-86644-894-5 |
language |
English |
format |
eBook |
author |
Schilling, Christopher |
spellingShingle |
Schilling, Christopher Analysis of Atrial Electrograms Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering |
author_facet |
Schilling, Christopher |
author_variant |
c s cs |
author_sort |
Schilling, Christopher |
title |
Analysis of Atrial Electrograms |
title_full |
Analysis of Atrial Electrograms |
title_fullStr |
Analysis of Atrial Electrograms |
title_full_unstemmed |
Analysis of Atrial Electrograms |
title_auth |
Analysis of Atrial Electrograms |
title_new |
Analysis of Atrial Electrograms |
title_sort |
analysis of atrial electrograms |
series |
Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering |
series2 |
Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering |
publisher |
KIT Scientific Publishing |
publishDate |
2012 |
physical |
1 electronic resource (VI, 214 p. p.) |
isbn |
1000029058 3-86644-894-5 |
illustrated |
Not Illustrated |
work_keys_str_mv |
AT schillingchristopher analysisofatrialelectrograms |
status_str |
n |
ids_txt_mv |
(CKB)4920000000101599 (oapen)https://directory.doabooks.org/handle/20.500.12854/40818 (EXLCZ)994920000000101599 |
carrierType_str_mv |
cr |
hierarchy_parent_title |
Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering |
is_hierarchy_title |
Analysis of Atrial Electrograms |
container_title |
Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering |
_version_ |
1787548505441566720 |
fullrecord |
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>01666nam-a2200349z--4500</leader><controlfield tag="001">993545325704498</controlfield><controlfield tag="005">20240102192202.0</controlfield><controlfield tag="006">m o d </controlfield><controlfield tag="007">cr|mn|---annan</controlfield><controlfield tag="008">202102s2012 xx |||||o ||| 0|eng d</controlfield><datafield tag="020" ind1=" " ind2=" "><subfield code="a">1000029058</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(CKB)4920000000101599</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(oapen)https://directory.doabooks.org/handle/20.500.12854/40818</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(EXLCZ)994920000000101599</subfield></datafield><datafield tag="041" ind1="0" ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Schilling, Christopher</subfield><subfield code="4">auth</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Analysis of Atrial Electrograms</subfield></datafield><datafield tag="260" ind1=" " ind2=" "><subfield code="b">KIT Scientific Publishing</subfield><subfield code="c">2012</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">1 electronic resource (VI, 214 p. p.)</subfield></datafield><datafield tag="336" ind1=" " ind2=" "><subfield code="a">text</subfield><subfield code="b">txt</subfield><subfield code="2">rdacontent</subfield></datafield><datafield tag="337" ind1=" " ind2=" "><subfield code="a">computer</subfield><subfield code="b">c</subfield><subfield code="2">rdamedia</subfield></datafield><datafield tag="338" ind1=" " ind2=" "><subfield code="a">online resource</subfield><subfield code="b">cr</subfield><subfield code="2">rdacarrier</subfield></datafield><datafield tag="490" ind1="1" ind2=" "><subfield code="a">Karlsruhe transactions on biomedical engineering / Ed.: Karlsruhe Institute of Technology / Institute of Biomedical Engineering</subfield></datafield><datafield tag="506" ind1=" " ind2=" "><subfield code="a">Open access</subfield><subfield code="f">Unrestricted online access</subfield><subfield code="2">star</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">This work provides methods to measure and analyze features of atrial electrograms - especially complex fractionated atrial electrograms (CFAEs) - mathematically. Automated classification of CFAEs into clinical meaningful classes is applied and the newly gained electrogram information is visualized on patient specific 3D models of the atria. Clinical applications of the presented methods showed that quantitative measures of CFAEs reveal beneficial information about the underlying arrhythmia.</subfield></datafield><datafield tag="546" ind1=" " ind2=" "><subfield code="a">English</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Classification</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Catheter Ablation</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Complex Fractionated Atrial Electrograms</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Atrial Fibrillation</subfield></datafield><datafield tag="653" ind1=" " ind2=" "><subfield code="a">Signal Processing</subfield></datafield><datafield tag="776" ind1=" " ind2=" "><subfield code="z">3-86644-894-5</subfield></datafield><datafield tag="906" ind1=" " ind2=" "><subfield code="a">BOOK</subfield></datafield><datafield tag="ADM" ind1=" " ind2=" "><subfield code="b">2024-01-03 03:18:48 Europe/Vienna</subfield><subfield code="f">system</subfield><subfield code="c">marc21</subfield><subfield code="a">2019-11-10 04:18:40 Europe/Vienna</subfield><subfield code="g">false</subfield></datafield><datafield tag="AVE" ind1=" " ind2=" "><subfield code="i">DOAB Directory of Open Access Books</subfield><subfield code="P">DOAB Directory of Open Access Books</subfield><subfield code="x">https://eu02.alma.exlibrisgroup.com/view/uresolver/43ACC_OEAW/openurl?u.ignore_date_coverage=true&portfolio_pid=5337920270004498&Force_direct=true</subfield><subfield code="Z">5337920270004498</subfield><subfield code="b">Available</subfield><subfield code="8">5337920270004498</subfield></datafield></record></collection> |