Novel MRI Technologies for Structural and Functional Imaging of Tissues with Ultra-short T? Values

Conventional MRI has several limitations such as long scan durations, motion artifacts, very loud acoustic noise, signal loss due to short relaxation times, and RF induced heating of electrically conducting objects. The goals of this work are to evaluate and improve the state-of-the-art methods for...

Full description

Saved in:
Bibliographic Details
Superior document:Schriften des Instituts für Mikrostrukturtechnik am Karlsruher Institut für Technologie / Hrsg.: Institut für Mikrostrukturtechnik
VerfasserIn:
Year of Publication:2017
Language:English
Series:Schriften des Instituts für Mikrostrukturtechnik am Karlsruher Institut für Technologie / Hrsg.: Institut für Mikrostrukturtechnik
Physical Description:1 electronic resource (XVII, 229 p. p.)
Tags: Add Tag
No Tags, Be the first to tag this record!
LEADER 02126nam-a2200469z--4500
001 993544313604498
005 20231214133139.0
006 m o d
007 cr|mn|---annan
008 202102s2017 xx |||||o ||| 0|eng d
020 |a 1000068880 
024 7 |a 10.5445/IR/1000065873  |2 doi 
035 |a (CKB)4920000000100896 
035 |a (oapen)https://directory.doabooks.org/handle/20.500.12854/54880 
035 |a (NjHacI)994920000000100896 
035 |a (EXLCZ)994920000000100896 
040 |a NjHacI  |b eng  |e rda  |c NjHacl 
041 0 |a eng 
050 4 |a RT48  |b .Ö946 2017 
082 0 4 |a 616.075  |2 23 
100 1 |a Özen, Ali Caglar,  |e author. 
245 1 0 |a Novel MRI Technologies for Structural and Functional Imaging of Tissues with Ultra-short T? Values 
260 |b KIT Scientific Publishing  |c 2017 
300 |a 1 electronic resource (XVII, 229 p. p.) 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
490 1 |a Schriften des Instituts für Mikrostrukturtechnik am Karlsruher Institut für Technologie / Hrsg.: Institut für Mikrostrukturtechnik 
520 |a Conventional MRI has several limitations such as long scan durations, motion artifacts, very loud acoustic noise, signal loss due to short relaxation times, and RF induced heating of electrically conducting objects. The goals of this work are to evaluate and improve the state-of-the-art methods for MRI of tissue with short T?, to prove the feasibility of in vivo Concurrent Excitation and Acquisition, and to introduce simultaneous electroglottography measurement during functional lung MRI. 
546 |a English 
653 |a HF Resonatoren 
653 |a T2 Relaxationszeit 
653 |a VollduplexMagnetic Resonance Imaging 
653 |a simultane Anregung und Auslese 
653 |a Magnetresonanztomographie 
653 |a Full Duplex 
653 |a T2 Relaxation 
653 |a RF Resonators 
653 |a Concurrent Excitation and Acquisition 
650 0 |a Magnetic Resonance Imaging. 
650 0 |a Diagnosis. 
776 |z 3-7315-0657-2 
906 |a BOOK 
ADM |b 2023-12-15 05:44:09 Europe/Vienna  |f system  |c marc21  |a 2019-11-10 04:18:40 Europe/Vienna  |g false 
AVE |i DOAB Directory of Open Access Books  |P DOAB Directory of Open Access Books  |x https://eu02.alma.exlibrisgroup.com/view/uresolver/43ACC_OEAW/openurl?u.ignore_date_coverage=true&portfolio_pid=5337576640004498&Force_direct=true  |Z 5337576640004498  |b Available  |8 5337576640004498