Systematic Study of Key Components for a Coaxial-Cavity Gyrotron for DEMO
The physical design of cavity and magnetron injection gun (MIG) for a realistic, DEMO-compatible, coaxial-cavity 238 GHz 2 MW CW fusion gyrotron is developed in this work, having auxiliary frequencies at 170 GHz and 204 GHz. Novel systematic approaches towards multi-frequency mode selection, magnet...
Saved in:
Superior document: | Karlsruher Forschungsberichte aus dem Institut für Hochleistungsimpuls- und Mikrowellentechnik |
---|---|
: | |
Year of Publication: | 2017 |
Language: | English |
Series: | Karlsruher Forschungsberichte aus dem Institut für Hochleistungsimpuls- und Mikrowellentechnik
|
Physical Description: | 1 electronic resource (XX, 236 p. p.) |