Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography / submitted by Andreas Hahn

eng: Positron emission tomography (PET) offers an excellent possibility to quantify proteins, such as receptors and transporters, in the living human brain. The gold standard for this quantification procedure is given by the arterial input function with the advantages of fewest modeling assumptions...

Full description

Saved in:
Bibliographic Details
VerfasserIn:
Place / Publishing House:2012
Year of Publication:2012
Language:English
Classification:44.09 - Medizintechnik
44.91 - Psychiatrie. Psychopathologie
Online Access:
Physical Description:122 Bl.; Ill., graph. Darst.
Notes:
  • Abweichender Titel laut Übersetzung der Verfasserin/des Verfassers
  • Zsfassung in dt. Sprache
Tags: Add Tag
No Tags, Be the first to tag this record!
id 990002755840504498
ctrlnum AC07814975
(AT-OBV)AC07814975
(Aleph)010075841ACC01
(DE-599)OBVAC07814975
(VLID)1716350
(EXLNZ-43ACC_NETWORK)990100758410203331
collection bib_alma
institution YWOAW
building MAG1-3
record_format marc
spelling Hahn, Andreas 1983- (DE-588)1322037078 aut
Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography submitted by Andreas Hahn
Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography
2012
122 Bl. Ill., graph. Darst.
Abweichender Titel laut Übersetzung der Verfasserin/des Verfassers
Zsfassung in dt. Sprache
Wien, Med. Univ., Diss., 2012
eng: Positron emission tomography (PET) offers an excellent possibility to quantify proteins, such as receptors and transporters, in the living human brain. The gold standard for this quantification procedure is given by the arterial input function with the advantages of fewest modeling assumptions and independence of nonspecific binding.<br />However, arterial cannulation is a laborious and demanding procedure which includes additional discomfort for the patient. Based on reference regions, several non-invasive modeling techniques have been applied with great success but their usage may be limited due to the underlying assumptions, especially within clinical comparisons and longitudinal designs. Image-derived input functions (IDIF) are extracted directly from PET images, hence, they represent a promising alternative to arterial blood sampling while maintaining independence of a reference region. However, various issues such as a robust definition of the input function and full substitution of manual arterial samples have complicated their application as a tool in clinical routine and research.<br />Here, we developed a novel combination of image-derived and venous input functions for the quantification of the major inhibitory serotonergic receptor (serotonin-1A, 5-HT1A) with the radioligand [carbonyl-11C]WAY-100635. The implementation of an optimized metabolite analysis showed excellent reproducibility of arterial by venous manual blood samples, enabling full independence of arterial cannulation.<br />Quantification of 5-HT1A receptor binding potentials (BPP) resulted in strong agreement between the introduced approach and the arterial input function in healthy subjects before (R 2=0.95) and after 8 weeks of hormone replacement therapy (R 2=0.93). Subsequent application of image-derived and venous input functions on a high resolution PET scanner in patients with major depression confirmed a widespread 30% decrease in 5-HT1A receptor binding (BPND and BPP) after electroconvulsive therapy.<br />To summarize, the combination of image-derived and venous input functions offers quantification of 5-HT1A receptor binding potentials entirely independent of arterial blood sampling. Importantly, reliable results were obtained for different study populations (healthy controls and patients with major depression), treatments (no intervention, pharmacological and electroconvulsive therapy), kinetic modeling approaches (regions of interest- and voxel-based) and PET scanners (standard and high resolution tomographs). The introduced technique offers great potential for application in clinical routine and research protocols and the thorough investigation within different settings encourages for further extension to other radioligands.
V:AT-OBV;B:AT-OeNB http://data.onb.ac.at/dtl/3630319 ONB-DTL Volltext OBV-ONB-DTL
V:AT-OBV;B:AT-ZBM text/html https://resolver.obvsg.at/urn:nbn:at:at-ubmuw:1-4245 ZBM Volltext OBV-EDOC-VL
YWOAW MAG1-3 41555-C.Stip. 2219874000004498
language English
format Thesis
Book
author Hahn, Andreas 1983-
spellingShingle Hahn, Andreas 1983-
Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography
author_facet Hahn, Andreas 1983-
author_variant a h ah
author_role VerfasserIn
author_sort Hahn, Andreas 1983-
title Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography
title_full Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography submitted by Andreas Hahn
title_fullStr Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography submitted by Andreas Hahn
title_full_unstemmed Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography submitted by Andreas Hahn
title_auth Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography
title_alt Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography
title_new Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography
title_sort optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography
publishDate 2012
physical 122 Bl. Ill., graph. Darst.
callnumber-raw 41555-C.Stip.
callnumber-search 41555-C.Stip.
url http://data.onb.ac.at/dtl/3630319
https://resolver.obvsg.at/urn:nbn:at:at-ubmuw:1-4245
illustrated Illustrated
work_keys_str_mv AT hahnandreas optimizednoninvasivequantificationofneuronalreceptorsinhealthyconditionandpsychiatricdisordersusingpositronemissiontomography
status_str n
ids_txt_mv (AT-OBV)AC07814975
AC07814975
(Aleph)010075841ACC01
(DE-599)OBVAC07814975
(VLID)1716350
(EXLNZ-43ACC_NETWORK)990100758410203331
hol852bOwn_txt_mv YWOAW
hol852hSignatur_txt_mv 41555-C.Stip.
hol852cSonderstandort_txt_mv MAG1-3
itmData_txt_mv 2014-02-28 01:00:00 Europe/Vienna
barcode_str_mv +YW18296807
callnumbers_txt_mv 41555-C.Stip.
inventoryNumbers_str_mv 2014-41555-C.Stip.
materialTypes_str_mv BOOK
permanentLibraries_str_mv YWOAW
permanentLocations_str_mv MAG1-3
inventoryDates_str_mv 20140228
createdDates_str_mv 2014-02-28 01:00:00 Europe/Vienna
holdingIds_str_mv 2219874000004498
is_hierarchy_id AC07814975
is_hierarchy_title Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography
basiskl_str_mv 44.09 - Medizintechnik
44.91 - Psychiatrie. Psychopathologie
basiskl_txtF_mv 44.09 - Medizintechnik
44.91 - Psychiatrie. Psychopathologie
_version_ 1797653521956339712
fullrecord <?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim"><record><leader>05105nam a2200541 c 4500</leader><controlfield tag="001">990002755840504498</controlfield><controlfield tag="005">20240229094342.0</controlfield><controlfield tag="007">cr#|||||||||||</controlfield><controlfield tag="007">tu</controlfield><controlfield tag="008">121221|2012 ||| m ||| 0 eng c</controlfield><controlfield tag="009">AC07814975</controlfield><datafield tag="015" ind1=" " ind2=" "><subfield code="a">OeBB</subfield><subfield code="2">oeb</subfield></datafield><datafield tag="024" ind1="7" ind2=" "><subfield code="a">urn:nbn:at:at-ubmuw:1-4245</subfield><subfield code="2">urn</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(AT-OBV)AC07814975</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">AC07814975</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(Aleph)010075841ACC01</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(DE-599)OBVAC07814975</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(VLID)1716350</subfield></datafield><datafield tag="035" ind1=" " ind2=" "><subfield code="a">(EXLNZ-43ACC_NETWORK)990100758410203331</subfield></datafield><datafield tag="040" ind1=" " ind2=" "><subfield code="a">ZBM</subfield><subfield code="b">ger</subfield><subfield code="c">VL-WG</subfield><subfield code="d">AT-UBMUW</subfield><subfield code="e">rakwb</subfield></datafield><datafield tag="041" ind1=" " ind2=" "><subfield code="a">eng</subfield></datafield><datafield tag="044" ind1=" " ind2=" "><subfield code="c">XA-AT</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.09</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">44.91</subfield><subfield code="2">bkl</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">WM 171</subfield><subfield code="2">nlm</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">WN 206</subfield><subfield code="2">nlm</subfield></datafield><datafield tag="084" ind1=" " ind2=" "><subfield code="a">QV 126</subfield><subfield code="2">nlm</subfield></datafield><datafield tag="090" ind1=" " ind2=" "><subfield code="h">g</subfield></datafield><datafield tag="100" ind1="1" ind2=" "><subfield code="a">Hahn, Andreas</subfield><subfield code="d">1983-</subfield><subfield code="0">(DE-588)1322037078</subfield><subfield code="4">aut</subfield></datafield><datafield tag="245" ind1="1" ind2="0"><subfield code="a">Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography</subfield><subfield code="c">submitted by Andreas Hahn</subfield></datafield><datafield tag="246" ind1="3" ind2=" "><subfield code="a">Optimized non-invasive quantification of neuronal receptors in healthy condition and psychiatric disorders using positron emission tomography</subfield></datafield><datafield tag="264" ind1=" " ind2="1"><subfield code="c">2012</subfield></datafield><datafield tag="300" ind1=" " ind2=" "><subfield code="a">122 Bl.</subfield><subfield code="b">Ill., graph. Darst.</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">Abweichender Titel laut Übersetzung der Verfasserin/des Verfassers</subfield></datafield><datafield tag="500" ind1=" " ind2=" "><subfield code="a">Zsfassung in dt. Sprache</subfield></datafield><datafield tag="502" ind1=" " ind2=" "><subfield code="a">Wien, Med. Univ., Diss., 2012</subfield></datafield><datafield tag="520" ind1=" " ind2=" "><subfield code="a">eng: Positron emission tomography (PET) offers an excellent possibility to quantify proteins, such as receptors and transporters, in the living human brain. The gold standard for this quantification procedure is given by the arterial input function with the advantages of fewest modeling assumptions and independence of nonspecific binding.&lt;br /&gt;However, arterial cannulation is a laborious and demanding procedure which includes additional discomfort for the patient. Based on reference regions, several non-invasive modeling techniques have been applied with great success but their usage may be limited due to the underlying assumptions, especially within clinical comparisons and longitudinal designs. Image-derived input functions (IDIF) are extracted directly from PET images, hence, they represent a promising alternative to arterial blood sampling while maintaining independence of a reference region. However, various issues such as a robust definition of the input function and full substitution of manual arterial samples have complicated their application as a tool in clinical routine and research.&lt;br /&gt;Here, we developed a novel combination of image-derived and venous input functions for the quantification of the major inhibitory serotonergic receptor (serotonin-1A, 5-HT1A) with the radioligand [carbonyl-11C]WAY-100635. The implementation of an optimized metabolite analysis showed excellent reproducibility of arterial by venous manual blood samples, enabling full independence of arterial cannulation.&lt;br /&gt;Quantification of 5-HT1A receptor binding potentials (BPP) resulted in strong agreement between the introduced approach and the arterial input function in healthy subjects before (R 2=0.95) and after 8 weeks of hormone replacement therapy (R 2=0.93). Subsequent application of image-derived and venous input functions on a high resolution PET scanner in patients with major depression confirmed a widespread 30% decrease in 5-HT1A receptor binding (BPND and BPP) after electroconvulsive therapy.&lt;br /&gt;To summarize, the combination of image-derived and venous input functions offers quantification of 5-HT1A receptor binding potentials entirely independent of arterial blood sampling. Importantly, reliable results were obtained for different study populations (healthy controls and patients with major depression), treatments (no intervention, pharmacological and electroconvulsive therapy), kinetic modeling approaches (regions of interest- and voxel-based) and PET scanners (standard and high resolution tomographs). The introduced technique offers great potential for application in clinical routine and research protocols and the thorough investigation within different settings encourages for further extension to other radioligands.</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="m">V:AT-OBV;B:AT-OeNB</subfield><subfield code="u">http://data.onb.ac.at/dtl/3630319</subfield><subfield code="x">ONB-DTL</subfield><subfield code="3">Volltext</subfield><subfield code="o">OBV-ONB-DTL</subfield></datafield><datafield tag="856" ind1="4" ind2="0"><subfield code="m">V:AT-OBV;B:AT-ZBM</subfield><subfield code="q">text/html</subfield><subfield code="u">https://resolver.obvsg.at/urn:nbn:at:at-ubmuw:1-4245</subfield><subfield code="x">ZBM</subfield><subfield code="3">Volltext</subfield><subfield code="o">OBV-EDOC-VL</subfield></datafield><datafield tag="970" ind1="1" ind2=" "><subfield code="c">34</subfield></datafield><datafield tag="970" ind1="2" ind2=" "><subfield code="a">ZBM</subfield><subfield code="d">HS-DISS</subfield></datafield><datafield tag="970" ind1="9" ind2=" "><subfield code="m">V:AT-OBV;B:AT-ZBM</subfield><subfield code="q">application/pdf</subfield><subfield code="u">http://media.obvsg.at/AC07814975-2001</subfield><subfield code="x">ZBM</subfield><subfield code="3">Volltext</subfield></datafield><datafield tag="970" ind1="0" ind2=" "><subfield code="a">OPUS28082</subfield></datafield><datafield tag="971" ind1="1" ind2=" "><subfield code="a">Lanzenberger, Rupert</subfield></datafield><datafield tag="971" ind1="3" ind2=" "><subfield code="a">2012-07</subfield></datafield><datafield tag="971" ind1="4" ind2=" "><subfield code="a">Dr. scient. med.</subfield></datafield><datafield tag="971" ind1="5" ind2=" "><subfield code="a">Medizinische Universität Wien</subfield><subfield code="b">Klinische Organisationseinheiten (Universitätskliniken und Klinische Institute)</subfield><subfield code="c">Universitätsklinik für Psychiatrie und Psychotherapie</subfield><subfield code="0">ioo:UMW:14633</subfield></datafield><datafield tag="971" ind1="8" ind2=" "><subfield code="a">Positronenemissionstomographie / Quantifizierung / Image-derived input functions / Serotonin-1A Rezeptor / Depression</subfield></datafield><datafield tag="971" ind1="9" ind2=" "><subfield code="a">positron emission tomography / quantification / image-derived input functions / serotonin-1A receptor / major depression</subfield></datafield><datafield tag="ADM" ind1=" " ind2=" "><subfield code="b">2024-04-25 06:39:16 Europe/Vienna</subfield><subfield code="d">20</subfield><subfield code="f">System</subfield><subfield code="c">marc21</subfield><subfield code="a">2018-12-24 09:42:55 Europe/Vienna</subfield><subfield code="g">false</subfield></datafield><datafield tag="HOL" ind1="8" ind2=" "><subfield code="b">YWOAW</subfield><subfield code="h"> 41555-C.Stip. </subfield><subfield code="c">MAG1-3</subfield><subfield code="8">2219874000004498</subfield></datafield><datafield tag="852" ind1="8" ind2=" "><subfield code="b">YWOAW</subfield><subfield code="c">MAG1-3</subfield><subfield code="h"> 41555-C.Stip. </subfield><subfield code="8">2219874000004498</subfield></datafield><datafield tag="ITM" ind1=" " ind2=" "><subfield code="9">2219874000004498</subfield><subfield code="e">1</subfield><subfield code="m">BOOK</subfield><subfield code="b">+YW18296807</subfield><subfield code="i">2014-41555-C.Stip.</subfield><subfield code="2">MAG1-3</subfield><subfield code="o">20140228</subfield><subfield code="8">2319873960004498</subfield><subfield code="f">02</subfield><subfield code="p">2014-02-28 01:00:00 Europe/Vienna</subfield><subfield code="h">41555-C.Stip.</subfield><subfield code="1">YWOAW</subfield><subfield code="q">2022-06-09 12:09:03 Europe/Vienna</subfield></datafield></record></collection>